The Data Handler may be used
as a stand-alone monitoring and control
device or integrated with other AGM and
manufacturers products. The following table
is a tool for constructing a model number
based on your specific design requirements.
Note - please contact our
Domain Engineering staff if you are unsure of which Data
Handler to specify for your application. Or e-mail or
fax us a block diagram of what you need and we will fill
in the model numbers and promptly provide you a Hardware
Overview and Proposal. We will also work with you to
develop OEM products.
Data Handler
Model Number Selection Table
Basic #
Input
Comm
Out
Description
Notes
SPM9000-
()
()
()
D
Any AC/DC Voltage/Current, Resistance or Thermocouple and 2
Contact Closures
Factory will set the Input to the specified input range prior
to shipment
C
8 Contact Closures.
P
Any Frequency, 2 Contact Closures
Specify frequency range and type
2
RS232C
4
RS485
I
4/20 mADC, 2 Contact Closures
V
0/10 VDC, 2 Contact Closures
8
Multiplexer (Mux) Interface
Used with SPM9000-N8R
Specific Models
SPM9000-
N
8
R
8 Input Mux
Use with SPM9000-D28 or SPM9000-D48
SPM9000-
T
R
A
RS485 to RS232C converter
Used to connect multiple RS485 devices together
SPM9000-
A
D
R
RS232C to RS232C converter
Used in systems with multiple ICS's that need to be
addressable
Following
are examples of Data Handler orders:
1. SPM9000-D2I, DC and 2 Contact inputs
with 4/20 mADC and 2 contact outs and RS232C
communications interface. I need two
independent adjustable setpoints and time
on/off delays for operating pumps based on a
wet well level signal.
2. SPM9000-D28 and SPM9000-N8R, 8 Channel analog
Data Logger that will be connected to a
Radio Modem for remote data acquisition.
Need AGM TakeCharge software to log and
display remote data on a portable PC.
Note: Be sure to include your name and a contact
number in case we have any questions
regarding your order.
Documentation - Select a
product from one of the following menus and
then click the 'Go' button
Analog - AC/DC
Voltage or Current, Thermocouple, RTD,
Potentiometer
Contact Closure Input
- Up to 8 contacts
Pulse Frequency Input -
Contact closure, Magnetic pickup, TTL, 10/30
VDC Pulse.
Multiplexer - Multiplex any combination of 8 DC Signals
and Contact Closures
Translators - RS232C
to RS485, Address, RS232C to Ethernet,
Intranet, Internet
As leased dedicated phone lines are
becoming more difficult to acquire, AGM customers are switching to
wireless data communications using AGM's Data Handlers (DH) and Spread
Spectrum Radios (SSR).
The Data Handler, when combined with your existing
pager system, provides a convenient, low cost way to detect and
broadcast remote site alarms such as a pump failure or unauthorized
intrusion.